1. INTRODUCTION
Whispering gallery mode (WGM) microresonators, such as microspheres and microtoroids, have attracted much interest for their potential application in label-free sensing of biomolecules, nanoparticles, and chemicals [1,2]. These resonators have ultrahigh quality () factors and small mode volumes, allowing for greatly enhanced light–matter interaction and high sensitivity to adsorbed analytes. Label-free, single particle level sensitivity to virus particles, proteins, nucleic acids, and even single ions has been demonstrated [3–9" target="_self" style="display: inline;">–9]. Currently, the sensing schemes are based on observing the change in the transmission spectrum of the resonator, appearing as either shift, splitting, or broadening of the resonance mode [7,8,10]. In essence, all of these sensing schemes measure the polarizability of the analyte, and WGM resonator sensors lack specificity beyond distinguishing entities with different polarizabilities. Although sensing specificity can be added to the system by surface functionalization, a complementary method to WGM sensing that can provide molecular fingerprints of the analyte without functionalization is desirable.
Raman spectroscopy is a widespread analytical technique that can be used for material identification without labeling or functionalization. Raman scattering is typically a weak process, but the introduction of surface-enhanced Raman scattering (SERS) has greatly improved the detection limit of Raman spectroscopy. In SERS, the analyte is placed on nanostructured metallic surfaces or metallic nanoparticles, typically made of coinage metals such as Au, Ag, and Cu, and the plasmonic “hotspots” produced by these metallic structures are used to enhance the Raman signal. A large enhancement factor on the order of has been reported from SERS, making Raman detection of single molecules possible [1113" target="_self" style="display: inline;">–13].
Large field enhancement, however, is not unique to plasmonic structures alone. Recently, the use of dielectric and semiconductor micro/nanostructures as a SERS substrate has received increasing attention [14–27" target="_self" style="display: inline;">–27]. These dielectric and semiconductor substrates, typically made of , Si, or , have several advantages over metallic SERS substrates. Dielectric SERS substrates are more stable under high-temperature and harsh electrochemical conditions [21,27], leading to a more repeatable SERS enhancement. Dielectrics also have reduced perturbation of the analyte both chemically and thermally [28,29]. In particular, the local heating of metallic nanostructures upon optical pumping can be significant [30], which can adversely affect the SERS substrate [31] and the analyte [29]. It has been shown that, in dielectric nanostructures, this heating can be negligible [15].
Dielectric SERS substrates can come in many forms, with microspheres or 2D/3D arrays of microspheres as one of the most popular forms. However, the exact mechanism for Raman enhancement in these dielectric microspheres is still not completely understood, due to the complexity that arises from the interplay among the many mechanisms involved [14]. Several enhancement mechanisms have been identified so far, with the most studied electromagnetic effects being photonic nanojets and WGM resonances, often also called morphology-dependent resonances in this context. Photonic nanojets are nonevanescent and nonresonant beams of light with enhanced field intensity, which are formed on the shadow side of the microspheres when the microspheres are illuminated from above. Due to the focusing of pump light at the nanojet, Raman signal from a sample under the microsphere is enhanced, typically by approximately a factor of 10–100 [16–20" target="_self" style="display: inline;">–20]. WGM resonances in these microspheres, on the other hand, are theoretically predicted to have Raman enhancement up to , comparable with metallic SERS substrates [32,33], but experimental demonstration of Raman enhancement from WGMs in dielectric microspheres has been limited and inconclusive thus far [17,21,22]. Other Raman enhancement mechanisms identified in arrays of microspheres and inverse opal structures include Fabry–Perot effects [17], photonic bandgap effects [23], and directional antenna effects [24]. Also, chemical enhancement attributed to charge transfer complexes is often observed from semiconductor substrates, such as and ZnO [25,26].
The difficulty in studying WGM enhancement mechanisms in microspheres mainly arises from the inefficiency in pumping the WGMs with a conventional micro-Raman spectroscopy setup, which is often designed for a conventional Raman signal or SERS signal from metallic substrates [13]. In dielectric microspheres, the linewidth of a typical WGM resonance is much narrower than that of plasmonic resonances in metallic nanostructures. In addition, these narrow WGMs often shift by more than their linewidths upon analyte adsorption or photothermal heating due to the pump light. Thus, although a fixed-wavelength excitation laser is suitable for pumping the broad plasmonic resonances, pumping the narrow and fluctuating WGMs poses a significant challenge. Further, because the dielectric microspheres that support WGMs are larger than the wavelength of excitation light, phase matching between the excitation beam and the WGMs can no longer be ignored, as in the case for plasmonic resonances from metallic nanoparticles. This leads to inefficient coupling of light from the free-space beam to WGMs, even when the wavelengths are matched. Inefficient coupling to WGMs from these factors often results in the effect of WGM enhancement being masked by other phenomena.
In this work, we study the WGM Raman enhancement mechanism by pumping a single silica microsphere through a tapered fiber coupler using a narrow-linewidth tunable laser. Tapered fiber couplers can couple more than 99% of the pump light into a single WGM in ideal conditions [34] and therefore have been routinely used for experiments with WGM resonator based sensors and microlasers [3,35]. By using a tapered fiber coupler to pump a single microsphere, we also avoid other electromagnetic effects in microspheres such as photonic nanojets. In addition, the use of a silica microsphere excludes the contribution of chemical enhancement. Thus, the entire Raman enhancement can be attributed to the WGM mechanism. From our result, we observed a clear enhancement of Raman scattering and modified Raman emission spectra due to WGMs. Our work demonstrates that significant Raman enhancement is possible using the same platform as that for WGM sensors, allowing for the two techniques to complement each other; Raman spectroscopy provides added molecular specificity to WGM resonator-based sensors, while the WGM resonator enhances the strength of the Raman signal.
2. EXPERIMENTAL METHODS
2.1 A. Fabrication of the Silica Microsphere
Silica microspheres were fabricated on a silicon chip, with each microsphere supported by a silicon “pillar” [3638" target="_self" style="display: inline;">–38]. Briefly, circular silica disks were lithographically defined and etched with HF. etching was used to undercut the circular disks, such that most of the disks were suspended in air, with only a small portion supported in the center by the silicon pillar. A subsequent irradiation by a laser reflowed the silica disk into a small microsphere (Fig. 1 inset).
Fig. 1. Schematic of the experimental setup. Inset: top view (left) and side view (right) of a typical on-chip microsphere used in the experiment.
下载图片 查看所有图片
2.2 B. Optical Setup
We used an in-house-built Raman spectrometer to collect the Raman emission from the microsphere, a schematic drawing of which is shown in Fig. 1. A fiber-coupled external cavity tunable laser (765–781 nm) was used to excite the WGM resonances. As the pump light travels through the fiber, it excites Raman scattering from the silica fiber, which can interfere with the Raman signal from the microsphere. An 800 nm short-pass filter was used to remove this contribution. After this filter, the pump light propagates through a tapered fiber, which was coupled with the microsphere. Finally, the transmitted light through the tapered fiber coupler was measured using a photodiode to monitor the coupling of the pump light to WGMs in the microsphere.
The Raman emission from the microsphere was collected from the top by a long working distance objective (). The objective was also used for imaging the microsphere resonator. In order to separate the Raman emission collection path from the imaging path, an 805 nm dichroic mirror was used. An 800 nm long-pass filter was used to remove the Rayleigh scattered pump laser, after which the Raman emission spectrum was recorded using a grating spectrometer.
A free-space excitation path was included in the setup to compare the tapered fiber excitation with conventional free-space excitation of Raman scattering. The same tunable laser was used for excitation; this laser was coupled to free space through a collimator, and a beam expander was used to adjust its beam size. A cleanup filter was used to remove the Raman emission generated in the fiber. The pump laser was focused on the microsphere through the same objective used for imaging.
For pumping with a tapered fiber coupler, the chip with a microsphere was mounted vertically on its side, and the light scattered from the WGMs was collected with the optical axis of the collection objective in the equatorial plane of the microsphere. Because most of the light from the microsphere is scattered in the equatorial plane due to radiation loss, this collection scheme is more efficient than collecting light scattered perpendicular to the equatorial plane. For free-space pumping, the chip was placed horizontally, so that the pump light was incident on the microsphere from the top.
2.3 C. Rhodamine 6G Coating
To study the microsphere’s Raman enhancement for surface-adsorbed molecules, we coated the surface of the microsphere with rhodamine 6G and studied the enhancement of its Raman scattering. 1 μL of 5 mg/mL rhodamine 6G solution in ethanol was dropped onto the chip with the microsphere and was dried in air [21]. The resonance wavelength of the pump WGM was measured before and after rhodamine 6G coating. From the shift in the WGM’s resonance wavelength, we estimated the thickness of rhodamine 6G on the microsphere to be 3.4 nm. The thickness of the rhodamine 6G layer on the substrate was estimated to be 200 nm based on the amount of rhodamine 6G deposited and was confirmed with a scanning electron microscope (SEM) measurement (image not shown). This large difference in the amount of analyte being pumped is important in calculating the enhancement factor, and being able to measure the amount of rhodamine 6G molecules on the microsphere through WGM resonance wavelength shift is a significant advantage in our system.
3. RESULTS AND DISCUSSION
Raman lasing in silica microsphere and microtoroid resonators is a well-known effect [35,39], but the occurrence of a Raman laser is detrimental for our work in Raman spectroscopy in two ways. First, the contribution from significant stimulated emission makes our estimate of Raman enhancement factor highly inaccurate. Second, any Raman laser in the microsphere may cause cascaded Raman lasing, which acts as secondary pumps that distort the measured Raman spectrum. To ensure there is no contribution from Raman lasing, we first characterized the lasing threshold in our microspheres, the result of which is shown in Fig. 2(a). The Raman lasing threshold was identified to be around 200 μW; for the subsequent experiments, the pump power was kept to below 100 μW to avoid contribution from stimulated Raman scattering. The inset in Fig. 2(a) shows the subthreshold portion of the Stokes light intensity; this part has linear dependence on pump power, as expected from spontaneous Raman scattering.
Fig. 2. Raman lasing and thermal effects in silica microspheres. (a) Raman intensity dependence on pump power for a bare silica microsphere. Inset shows the linear dependence of Raman intensity on pump power in the spontaneous Raman emission regime. (b) Measured transmission spectrum through the fiber taper coupler around a typical WGM resonance. Inset shows the transmission spectrum (blue curve) of the same modes at a higher power typically used for Raman pumping, with significant thermal broadening. The red triangular waveform corresponds to the scanning of the pump laser wavelength; the left half corresponds to a decreasing pump wavelength, while the right half corresponds to an increasing pump wavelength. The oscillation seen in the thermally broadened WGM is due to interference effect from reflection at fiber ends, which is unrelated to the WGM resonance.
下载图片 查看所有图片
We first excited Raman scattering in a bare silica microsphere to characterize the effect of WGM resonance on silica Raman scattering. A microsphere with a diameter of 13.8 μm and a WGM at 767.54 nm with an intrinsic -factor of was used for this measurement [Fig. 2(b)]. The resonance mode is split into two due to the coupling of clockwise and counterclockwise traveling wave modes. At high power, there was strong thermal broadening in the observed transmission spectrum of the WGM, as presented in the Fig. 2(b) inset. This broadening arises due to the shift in the resonance wavelength caused by the heat generated by the pump light, and several picometers of resonance wavelength shift are observed regularly even for modest pump power (few tens of μW) [40]. This suggests that, without a tunable laser and active monitoring of the WGM, it is difficult to couple a high-intensity pump light efficiently into the WGM because, as soon as the pump light is coupled in, the WGM shifts, reducing its spectral overlap with the pump light. In our experiment, we keep the pump light scanning across the WGM during Raman signal collection and calculate from the transmission spectrum the fraction of pump power coupled into the resonator on average (typically 0.2–0.5, see Appendix A); this fraction is accounted for when we compare the Raman intensity from different spectra. Although the pump efficiency is not ideal, we find that this method results in a stable and quantifiable coupling of the pump power into the WGM over the spectrometer’s integration time.
Figure 3(a) presents the observed Raman emission from the silica microsphere with pump light on resonance with a WGM. The spectrum consists of a broad background that corresponds to the Raman features of bulk silica as well as numerous sharp peaks. These sharp peaks are the result of the modified density of states from WGM resonance (i.e., the Purcell effect); each of these peaks corresponds to a WGM of the microsphere resonator, with a periodicity that agrees with the calculated free spectral range. Due to slight eccentricity of the microsphere, we have eccentricity-induced splitting, and the WGMs appear in several “groups” of closely spaced modes [39]. The WGM peaks correspond to the Raman emission from silica that is first emitted into the WGMs and then scattered to free space to be collected by the objective. On the other hand, the broad background corresponds to the Raman emission that is not coupled to WGMs but instead emitted directly into free space. As a result, there is a notable spatial variation in the Raman emission from the silica microsphere, as shown in Fig. 3(b); the WGM peaks are much more prominent at the two edges of the resonator than at the center of the resonator, indicating that these peaks correspond to the light lost from the WGMs due to the perturbed total internal reflection from the curvature of the microsphere. Also, this emission pattern indicates that the emission from the two sides of the resonator is approximately equal. This confirms that Raman scattering has equal intensity in the forward scattering and backward scattering directions.
Fig. 3. Raman emission from a bare silica microsphere. (a) Integrated Raman spectrum from a 13.8 μm silica microsphere. (b) Raman spectra from different positions in the microsphere. Red dotted circles in the inset indicate the positions from which the spectra were collected. (c) Measured Raman intensity dependence on pump detuning. Red curve shows a Lorentzian fit to the experimental data.
下载图片 查看所有图片
With this silica microsphere resonator, we have investigated the dependence of Raman intensity on the wavelength detuning of the pump from a resonance [Fig. 3(c)]. There is a large enhancement in the collected Raman signal when the pump is on resonance with a WGM. This enhancement can be mostly attributed to the power enhancement of the pump light in the resonator. At critical coupling, the power enhancement is [41] where is the wavelength detuning of the pump light, is the free spectral range of the optical cavity, and is the linewidth of the optical mode. For our resonator, we have and , resulting in at zero detuning. To compare this value to the one obtained in our experiment, we note that, at the detuning of , we have . Thus, by taking the ratio of the peak Raman intensity at zero-detuning and at 0.014 nm detuning, we obtain the experimentally measured Raman enhancement to be , in good agreement with the theoretically predicted value. The discrepancy between the two can be attributed to the nonideal pumping at zero detuning and the contribution of background light in the Raman spectra for detuned pump, where the Raman signal is low.
In calculating the above theoretical enhancement factor, we have ignored the contribution from the Purcell effect, which clearly modifies the Raman spectrum and causes the sharp peaks to appear. Because the Raman spectrum of silica is broad and spans over several free-spectral ranges, we expect little enhancement in the total power of the emitted Stokes light due to the Purcell effect [33,42]. However, within the linewidth of a particular WGM, the Purcell enhancement in the Raman spectral density is significant. The enhancement in Raman spectral density can be estimated by integrating the background-subtracted intensity within a WGM peak, dividing it by the linewidth of the WGM, and comparing the result to the silica background Raman intensity. It is important to note here that the width of WGM peaks in the Raman spectrum is limited by the spectrometer and is not the true linewidth; instead, we assume the linewidth of the Stokes WGM to be the same as the pump mode, at . From this, we estimate the spectral density enhancement within a WGM due to the Purcell effect to be .
Next, we studied the enhancement of the Raman signal from rhodamine 6G molecules coated on the surface of a silica microsphere. We compared the Raman spectra from rhodamine 6G excited in three different ways. The first is the excitation of rhodamine 6G on a microsphere that is resonantly pumped through a tapered fiber coupler, as previously described for the bare silica microsphere. The second is the excitation of rhodamine 6G on the substrate near the microsphere with a free-space Gaussian beam, with an estimated beam diameter of 7 μm. This measurement serves as a control where no Raman enhancement due to the microsphere is present. The third is the free-space beam excitation of the rhodamine 6G on the microsphere, which serves as a comparison with previously published results on microsphere-based Raman enhancement with conventional micro-Raman setups [17–21" target="_self" style="display: inline;">–21]. The excitation beam is directed onto the rhodamine 6G coated microsphere from the top in this third case.
The observed Raman spectra for rhodamine 6G on the microsphere is presented in Fig. 4(a). Another microsphere with a diameter of 17.3 μm was used for this measurement. The pump wavelength was 769 nm for pumping with a tapered fiber coupler and 770 nm for free-space pumping. The modified Raman emission due to the Purcell effect is only visible for the microsphere pumped by the fiber taper. This can be attributed to the higher WGM coupling efficiency from the tapered fiber pumping; the Stokes light only couples to a WGM when the Raman scatterer has spatial overlap with the Stokes WGM, and this coupling is more efficient when the pump light is also in a WGM. For the peak at , there are two sharp peaks from tapered fiber pumping but only one broad peak, which corresponds to the bulk Raman spectrum, from free-space pumping of the microsphere or the substrate. This can be attributed to the modified Raman emission in the presence of an optical cavity; two WGMs overlap with the Raman peak at , and there is selective enhancement of Raman scattering at the resonance wavelengths of these two WGMs, leading to what looks like two peaks. By comparing the integrated area of the rhodamine 6G peak at over a spectral band of , we find the Raman intensity from the tapered fiber pumped microsphere to be larger than the Raman intensity from rhodamine 6G on the substrate by a factor of 928. Similarly, we find the Raman intensity for the free-space pumped microsphere to be seven times larger than the Raman intensity from rhodamine 6G on the substrate, which is in agreement with previously published results [16–19" target="_self" style="display: inline;">–19]. Free-space pumping is expected to have little coupling to WGMs, and the enhancement in Raman intensity from free-space pumping of the microsphere is expected to be mostly due to the photonic nanojet effect. Our results clearly show that the enhancement from WGMs can be much higher than that from a photonic nanojet.
Fig. 4. Raman enhancement of rhodamine 6G through the silica microsphere. (a) Background subtracted Raman spectra of rhodamine 6G for tapered fiber coupler excitation (blue), free-space excitation on a microsphere (red), and free-space excitation on the substrate (green). The spectra for free-space excitation on the microsphere and substrate are scaled by 100 times for visibility. (b) Raman spectrum of rhodamine 6G around the peak, obtained from subtracting the spectrum after photobleaching from the spectrum before photobleaching. The solid green curve is a fit to the data points. The spectrum is fitted as sum of a Lorentzian Raman peak (purple dotted curve) and two Gaussian WGM peaks (red dotted curve).
下载图片 查看所有图片
From the spectra in Fig. 4(a), we can identify two mechanisms for the Raman enhancement: the pump enhancement, which uniformly increases the Raman intensity at all Stokes wavelengths, and the Purcell enhancement, which results in enhancement at Stokes wavelengths matching WGMs only, resulting in Raman spectra modified by sharp resonance peaks. The total Raman enhancement can be approximated as . This is analogous to the electromagnetic mechanism in SERS, in which, approximately a factor of is attributed to pump enhancement, and another factor of is attributed to radiation enhancement resulting in a total of enhancement when the Stokes shift is small [11,13]. In what follows, we consider these two enhancement mechanisms in silica microsphere separately and provide a theoretical estimate of the enhancement factors due to each mechanism. We follow the theoretical analysis in recent works on the Purcell-enhanced Raman scattering in Fabry–Perot optical microcavities [43–46" target="_self" style="display: inline;">–46].
The pump enhancement factor for molecules adsorbed on the surface of a microsphere can be calculated from the power enhancement factor, as previously discussed, with correction terms that account for the local electric field strength at the surface of the microsphere, the thickness of rhodamine 6G on the microsphere and that on the substrate, and the reduced pump efficiency due to laser scanning. In the pump enhancement factor (), we include these factors that affect the effective pump intensity leading to a spectrally uniform scaling of the Raman intensity, i.e., the factors that do not distort the shape of the original spectrum. The pump enhancement factor can be expressed as where and are the effective volumes of rhodamine 6G being excited by WGM [47] and free-space pumping, respectively, is the cross-sectional area of the WGM, is the effective cross-sectional area of the free-space pump beam, and is a correction factor to account for the reduced pump efficiency from the scanning pump laser. This microsphere with rhodamine 6G coating has and . For our experiment with the spectrum shown in Fig. 4, we obtain . The details of this calculation are presented in Appendix A.
In addition to pump enhancement, Raman emission is also enhanced by the increased density of state due to resonance, characterized by the Purcell factor. Whereas the pump enhancement results in a uniform enhancement of the entire Raman spectrum, the Purcell enhancement only enhances the Raman spectral density within the linewidth of a WGM and thus is highly nonuniform, introducing sharp peaks in the Raman spectra. The Purcell enhancement factor, however, is calculated for the enhancement of total Raman intensity for a particular Raman peak and, thus, is much smaller than the enhancement of Raman spectral density within each WGM linewidth. The ideal Purcell factor is often written as , where is the cavity -factor, and is the mode volume of the Stokes WGM [48,49]. Several corrections are required in applying this Purcell factor to our experiment. First, there is a correction to the Purcell factor due to the optical cavity having a refractive index rather than being in vacuum. Second, WGMs typically have narrower linewidth than Raman peaks, which leads to nonuniform enhancement in Raman scattering throughout the Raman peak. Instead of , the effective increase in the total emitted power over the entire Raman peak is characterized with an effective -factor , with defined as , where is the linewidth of the Raman peak [43]. Also, the derivation of assumes there is a single WGM at the center of the Raman peak, but in practice there may be multiple WGMs that overlap with the Raman peak with some detuning. This spectral overlap between WGM and Raman peak is accounted for by introducing . Third, the ideal Purcell factor assumes that the emitter lies at the maximum of the cavity field, but this is not true for microspheres supporting WGMs. Thus, we need to correct for the local electric field strength at the surface of the microsphere, where the rhodamine 6G molecules are, as well as the overlap between the pump WGM and the Stokes WGM. This is accounted for by . Fourth, the Purcell-enhanced Raman scattering is emitted into the Stokes WGM first and then scattered into free space; this emission has a different emission pattern compared with that of Raman scattered light emitted directly into free space. As a result, the fraction of light collected by the objective is different for each type of emission, and we introduce to account for this difference in collection efficiency. Fifth, there is a twofold degeneracy in mode density due to the microsphere having both clockwise and counterclockwise WGM, which doubles the Purcell-enhanced Raman emission. Last, some of the light in the Stokes WGM is coupled into the fiber taper and is not collected from the microscope objective. We assume critical coupling to the Stokes mode; in this case, half of the Stokes light is lost through the fiber taper, thus reducing the collected Raman signal by a half. Combining these effects, we obtain
We evaluate the Purcell enhancement factor for the Raman spectrum presented in Fig. 4(a), with , , , , , , and to obtain . Details of this calculation are presented in Appendix B.
To compare the theoretical results to the experiment, we performed curve fitting to the experimentally obtained Raman spectra to estimate the contribution of the Purcell enhancement in the total Raman enhancement. This is possible because the Purcell enhancement appears as sharp lines that are clearly distinguishable from the bulk Raman spectrum. However, to determine the Purcell enhancement accurately, we need a Raman spectrum corresponding to only that of rhodamine 6G, without any background contribution from silica. In order to obtain such a spectrum, we noted that, as we pump the rhodamine 6G coated microsphere, the Raman peaks of rhodamine 6G gradually decreased and eventually disappeared, likely due to photobleaching of the dye (Appendix C). The difference in the Raman spectrum of a freshly coated microsphere and that of a microsphere pumped for a long time corresponds to the Raman spectrum from rhodamine 6G alone without any silica contribution [Fig. 4(b)]. In performing the curve fitting, the bulk Raman peak was assumed to have a Lorentzian lineshape, whereas the two WGMs had spectrometer-limited linewidth and were fitted with Gaussians. By comparing the integrated areas of the bulk Raman peak and the two WGM peaks, we estimated the Purcell enhancement to be 0.134. This measured Purcell enhancement is in very good agreement with the theoretically calculated value of 0.127. Further, we can also calculate the experimentally measured to be 818. This is also in good agreement with the theoretically calculated value of 1204.
Finally, the Raman enhancement factor of the silica microsphere as an SERS substrate is evaluated as where and are the Raman signal intensity in the SERS and non-SERS spectra, and and are the effective number of molecules being excited in the SERS and non-SERS measurement [12]. Here, , and the ratio is calculated from the effective volume of rhodamine 6G excited in each pumping scheme (Appendix D). From this, we obtain . Within this, a minor factor of 1.134 can be attributed to the Purcell enhancement, with the remaining attributed to pump enhancement.
4. CONCLUSION
In conclusion, we have measured the enhanced Raman emission of silica and rhodamine 6G due to WGM resonances in silica microspheres. Our use of a tapered fiber coupler allows us to couple pump light to the WGMs with high efficiency, leading to a higher enhancement factor than is possible with free-space pumping. We estimated the Raman enhancement factor as , with most of the enhancement originating from the pump enhancement and a small factor of 1.134 from the Purcell enhancement. These experimentally measured results are in good agreement with theoretical calculations.
The experimentally observed enhancement factor in this work is, to the best of our knowledge, the largest reported from dielectric microspheres so far but still several orders lower than predicted in theory [32,33], which can be as high as . The largest contributing factor that leads to this smaller experimentally measured enhancement factor is the large linewidth of the rhodamine 6G Raman peak, with , compared with that of the Stokes WGM, with linewidth on the order of . Because the Raman peak linewidth is different for different molecules, this factor is often not included in theoretical calculations of the enhancement factor, making the enhancement factor predicted from theory larger than what is attainable for common Raman probes. On the other hand, for some gas phase molecules such as , the Raman peaks can be much narrower and comparable with WGMs in linewidth [44]. These molecules would result in a much larger enhancement factor from WGMs, predominantly due to an increase in Purcell enhancement. Also, cavity resonance scanning techniques similar to those demonstrated for Fabry–Perot cavities may allow us to obtain a higher Purcell enhancement by scanning the Stokes WGM across the Raman peak [4446" target="_self" style="display: inline;">–46].
An interesting question to consider here is whether dielectric microspheres as SERS substrates have the potential to detect single-molecule Raman spectra. Despite earlier works that have taken single-molecule SERS as an indication for extremely high enhancement factors, it has been recently demonstrated that, when Raman probes with a large cross section such as rhodamine 6G are pumped at their molecular resonance, a single-molecule EF as low as is sufficient to observe single molecule SERS [50]. Considering this result, we believe that single-molecule SERS is attainable with dielectric microspheres with some optimization. First, we note that, without any rhodamine 6G coating, a -factor above is easily achievable with bare silica microspheres. For single-molecule studies, the perturbation to the WGM would be minimal, and we do not expect any lowering of the -factor from that of a bare silica microsphere. The increased -factor alone would increase the EF by more than an order of magnitude. Also, for single molecules there is no inhomogeneous broadening [51], leading to a narrower Raman peak and an increased Purcell enhancement from WGMs. Together, with further optimization in the size and refractive index of the microsphere, we believe that a single-molecule EF of is realistic for dielectric microspheres supporting WGMs. Although challenges such as the suppression of Raman lasing remains, the demonstration of single-molecule SERS from dielectric microspheres would allow for the probing of molecular dynamics and interactions at previously unattainable levels of details.
A unique advantage of our system, not fully exploited in this work, is the ability to quantitatively measure the number of molecules adsorbed onto the microsphere from a resonance wavelength shift and collect the Raman spectra from the same molecules. Wavelength shift provides another measurement of the number of molecules being excited, independent from Raman spectroscopy. This allows for more accurate quantification of the enhanced Raman spectra. On the other hand, molecular identification through Raman spectroscopy adds otherwise unavailable specificity to the WGM sensing method. This combination of two detection methods can potentially be much more powerful in chemical and biological sensing compared with each method used alone.
5 Acknowledgment
Acknowledgment. The authors thank Huzeyfe Yilmaz and Weijian Chen for helpful discussions.
Steven H. Huang, Xuefeng Jiang, Bo Peng, Corey Janisch, Alexander Cocking, Şahin Kaya Özdemir, Zhiwen Liu, Lan Yang. Surface-enhanced Raman scattering on dielectric microspheres with whispering gallery mode resonance[J]. Photonics Research, 2018, 6(5): 05000346.