摘要
为了较快、较高准确度地检验大波差的非球面或球面,将一个液晶显示器作为低频光栅和移相装置被用于朗奇检验,在小液晶显示器上由计算机生成光栅图,代替普通光栅和步进电机.消除了因电机移动引起的移相误差,消除了因转动光栅的角度不能正好达到90°而引起的误差.以一个非球面为例,做了移相测试及波面复原.实验表明液晶显示器可作为一个光栅和移相装置.
Abstract
A small liquid crystal display that acted like a grating and phase-shifting device was used on Ronchi test,to measure a spheric or an aspheric of large wavefront aberration,more quickly and accurately.Instead of a common grating and a step motor,a movable image of grating is shown on the liquid crystal display. This gets rid of the phase-shifting error caused by the motor moving,and the error caused by grating revolve angle not being just 90°. A phase-shifting algorithm is used to test an aspheric,and the wavefront aberration of the aspheric is restored. The experiment shows that a small liquid crystal display can be used a grating and phase-shifting device.
参考文献

[1] Yatagai I T. Fringe scanning Ronchi test for a spherical surfaces. Applied Optics,1984,23(20): 3676~3679

[2] Yatagai I T. Phase measuring Ronchi test. Applied Optics,1988,27(3): 523~528

[3] 林桂粉,陈磊,陈迸榜.朗契检验相位探测和波面恢复.光子学报,1996,25(12):1125~1230

    Lin G F,Chen L,Chen J B. Acta Photonica Sinica,1996,25(12): 1125~1130

[4] 钟金刚.用于定量分析朗契图的四步相移算法.南昌大学学报(工科版),1998,20(4):97~102

    Zhong J G. Journal of Nanchang University(Engineering and Technology),1998,20(4): 97~102

[5] 郁道银.工程光学.北京:中国机械出版社,1999,10:100~330

    Yu D Y. Technology optics. Beijing: China Machine Press,1999,10: 100~300

[6] 张善钟.计量光栅技术.北京:中国机械出版社,1985,12:48~50

    Zhang S Z. Metrology Grating Technology. Beijing:China Machine Press,1985,12: 48~50

[7] 潘君骅.计量测试技术手册:第10卷.北京:中国计量出版社,1997.666~668,677~678

    Pang J H. Handbook of Measurement Technology:Volume 10.Beijing: China Metrology Press,1997.666~668,677~678

[8] 陈磊,高志山,何勇.红外光学透镜焦距侧量.光子学报,2004,33(8):986~988

    Chen L,Gao Z S,He Y. Acta Photonica Sinica,2004,33(8): 986~988

[9] Ding X X. An adaptive wavelet transform via lifting for image compression. Acta Photonica Sinica,2004,33(2):225~228

[10] 孙深,沈亦兵,白剑.Ronchi光栅Talbat效应长焦距测量的准确度极限研究.光子学报,2004,33(10):1214~1217

    Sun S,Shen Y B,Bai J. Acta Photonica Sinica,2004,33(10): 1214~1217

席庆奎, 陈磊, 李迎春, 白雪莲, 朱日宏. 一种朗契检验新方法[J]. 光子学报, 2006, 35(3): 0452. Xi Qingkui, Chen Lei, Li Yingchun, Bai Xueliang, Zhu Rihong. A New Ronchi Test Method[J]. ACTA PHOTONICA SINICA, 2006, 35(3): 0452.