Photonics Research, 2021, 9 (2): 02000193, Published Online: Jan. 29, 2021   

Ultra-wide-dynamic-range gas sensing by optical pathlength multiplexed absorption spectroscopy Download: 661次

Author Affiliations
1 School of Physics, Harbin Institute of Technology, Harbin 150001, China
2 National Key Laboratory of Science and Technology on Tunable Laser, Harbin Institute of Technology, Harbin 150001, China
Figures & Tables

Fig. 1. Basic principle of OPMAS. The upper part is the basic configuration including an FMCW interferometer equipped with a gas cell having multiple internal reflections. The lower part is the procedure for the retrieval of spectral signals with different absorption pathlengths.

下载图片 查看原文

Fig. 2. Simulation of spectral signal retrievals with different OPLs using an MPC. (a) Original reflection-mode beat signals in spectral domain for 1000 ppm acetylene gas. The inset shows the local details of the beat signal. (b) DFT results in spatial domain containing 233 RPs. (c) Enlargement of the beginning part of (b). (d), (e) Retrieved spectral signals from two RPs (#1 and #15) for three different gas concentrations (60 ppm, 1000 ppm, and 1.6%). (f) Simulated spectral signals in the transmission mode.

下载图片 查看原文

Fig. 3. Experimental setup of the OPMAS. FRM, Faraday rotation mirror; PC, polarization controller; BPD, balanced photodetector; ATT, optical attenuator; DAQ, data acquisition.

下载图片 查看原文

Fig. 4. Experimental results of spectral signal retrieval at different reflection points in the MPC filled with 9250 ppm acetylene. (a) Acquired raw beat signals. (b) DFT of the signals shown in (a) with 50 results averaged. (c), (d) Enlargements of the beginning and end parts of (b). (e), (f) Spectral signals retrieved by IDFT from the RPs #1 and #13 shown in (c).

下载图片 查看原文

Fig. 5. Measured and simulated transmission spectra of acetylene at different concentrations with different absorption pathlengths. (a)–(d) For acetylene concentrations of 9.8%, 9250 ppm, 1120 ppm, and 95 ppm, with absorption pathlengths of 0.359 m, 0.359 m, 4.322 m, and 19.449 m, respectively.

下载图片 查看原文

Fig. 6. Measurement results of 9.3 ppm acetylene in the transmission mode. (a) Original transmission signal acquired in one period of the laser scan. (b) Measured transmission spectrum with 10 scans averaged and the corresponding HITRAN-simulated result.

下载图片 查看原文

Fig. 7. Plot of α(ν0) value versus gas concentration. Each error bar, magnified 10 times for clarity, shows the SD of five measurement results.

下载图片 查看原文

Table1. Details of Experimental Data Used for Evaluating the Dynamic Range of Gas Sensing

Concentration[ppm]SignalL[m]T(ν0)α(ν0)[m1]Uα[m1]
98,000RP #10.3590.013811.9380.048
9250RP #10.3590.63621.26110.0073
1120RP #124.3220.53950.142800.00021
95RP #5419.4490.78510.012370.00016
9.3Transmission41.9610.94960.001230.00001

查看原文

Table2. Comparison of Typical State-of-the-Art Laser Spectroscopic Gas Sensors

TechniqueaPrincipleGasWavelength [μm]Dynamic rangeRef.
OPMASAbsorptionC2H21.521.9×106This work
TDLASAbsorptionH2O1.37103[14]
CRDSAbsorptionNO5.262×103[26]
OA-ICOSAbsorptionH2S1.591.1×104[27]
SCARAbsorptionC14O2164.5103[28]
PASPhotoacousticC2H21.5323.1×105[17]
PTSPhotothermalC2H21.5332×107[19]
RSRaman scatteringH21.5333.3×105[21]
CMDSDispersionCO1.562×105[23]

查看原文

Xiutao Lou, Yabo Feng, Shunhu Yang, Yongkang Dong. Ultra-wide-dynamic-range gas sensing by optical pathlength multiplexed absorption spectroscopy[J]. Photonics Research, 2021, 9(2): 02000193.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!