强激光与粒子束, 2011, 23 (8): 2017, 网络出版: 2011-09-20  

辐射变色膜片对质子剂量响应的实验标定

Calibration of dose response of radiochromic film to protons
洪伟 1,2,*刘东晓 1,2,3滕建 1,2焦春晔 1,2伍波 1,2谷渝秋 1,2
作者单位
1 中国工程物理研究院 激光聚变研究中心, 四川 绵阳 621900
2 中国工程物理研究院 等离子体物理国家重点实验室, 四川 绵阳 621900
3 中国工程物理研究院 研究生部, 四川 绵阳 621900
摘要
利用串列静电加速器产生的5~9 MeV的质子束对HD-810型辐射变色膜片(RCF)进行了标定。用分光光度计和普通的商用平板扫描仪对辐照后的RCF透过率进行了测量,得到了光学密度变化随RCF灵敏层吸收剂量的变化曲线。标定实验结果表明:在一定的吸收剂量范围内,RCF的光学密度变化与RCF灵敏层中吸收剂量成线性关系,并且与质子能量无关。测量光学密度所用光源的波长对线性范围的大小有较大影响,绿光(532 nm)比红光(670 nm)有更大的剂量探测范围。
Abstract
The calibration of radiochromic films (HD-810) irradiated by protons with different energies has been carried out on the tandem electrostatic accelerator. The optical densities of the irradiated films were obtained using spectrophotometer and commercial flatbed scanner, and the curves of the net optical densities versus dose were acquired. The results of calibration corroborate that, in a certain range of absorbed dose, the net optical densities vary linearly with absorbed doses of the sensitive layer and are independent on the energy of protons. The wavelength of light used to measure the optical density has great effect on the linear range, and the linear range of green light (532 nm) is obviously larger than that of red light (670 nm).
参考文献

[1] Stanislav M. Vatnitsky radiochromic film dosimetry for clinical proton beams[J]. Appl Radiat Isot, 1997, 48(5):643-651.

[2] Avila-Rodriguez M A, Wilson J S, McQuarrie S A. The use of radiochromic films to measure and analyze the beam profile of charge[J]. Appl Radia Isot, 2009, 67(11):2025-2028.

[3] Snavely R A, Key M H, Hatchett S P, et al. Intense high-energy proton beams from petawatt-laser irradiation of solids[J]. Phys Rev Lett, 2000, 85(14):2945-2948.

[4] Roth M, Blazevic A, Geissel M, et al. Energetic ions generated by laser pulses: a detailed study on target properties[J]. Phys Rev ST Accel Beams, 2002, 5:061301.

[5] Mackinnon A J, Sentoku Y, Patel P K, et al. Enhancement of proton acceleration by hot-electron recirculation in thin foils irradiated by ultraintense laser pulses[J]. Phys Rev Lett, 2002, 88:215006.

[6] Allen M, Patel P K, Mackinnon A, et al. Direct experimental evidence of back-surface ion acceleration from laser-irradiated gold foils[J]. Phys Rev Lett, 2004, 93:265004.

[7] Vatnitsky S M, Schulte R W, Galindo R, et al. Radiochromic film dosimetry for verification of dose distributions delivered with proton-beam radiosurgery[J]. Phys Med Biol, 1997, 42(10):1887-1898.

[8] Buenfil A E, Ruiz-Trejo C, Gamboa-deBuen I, et al. Response of radiochromic dye films to low energy heavy charged particles[J]. Nucl Instrum Meth in Phys Res B, 2002, 197(3/4):317-322.

[9] Hey D S, Key M H, Mackinnon A J, et al. Use of GafChromic film to diagnose laser generated proton beams[J]. Rev Sci Instrum, 2008, 79:053501.

[10] Niroomand-Rad A, Blackwell C R, Coursey B M, et al. Radiochromic film dosimetry: recommendations of AAPM radiation therapy committee task group 55[J]. Med Phys, 1998, 25(11):2093-2115.

洪伟, 刘东晓, 滕建, 焦春晔, 伍波, 谷渝秋. 辐射变色膜片对质子剂量响应的实验标定[J]. 强激光与粒子束, 2011, 23(8): 2017. Hong Wei, Liu Dongxiao, Teng Jian, Jiao Chunye, Wu Bo, Gu Yuqiu. Calibration of dose response of radiochromic film to protons[J]. High Power Laser and Particle Beams, 2011, 23(8): 2017.