作者单位
摘要
1 中国科学院上海光学精密机械研究所高功率激光单元技术研发中心, 上海 201800
2 中国科学院上海光学精密机械研究所高功率激光物理国家实验室, 上海 201800
测试了应用于神光Ⅱ系列装置93片N31型钕玻璃的小信号增益系数。结果表明,Nd2O3质量分数为2.2%的钕玻璃平均小信号增益系数为0.0387 cm-1,Nd2O3质量分数为3.0%的钕玻璃平均小信号增益系数为0.0416 cm-1,两种浓度的钕玻璃不同样品间小信号增益系数的起伏范围分别为0.86%和0.76%。根据所测定的增益值,表明N31型钕玻璃的增益起伏符合神光Ⅱ系列装置要求,为实现该装置中每一路增益性能的平衡提供了有力保障,也为今后对更大尺寸钕玻璃增益性质的控制提供了经验。
激光器 钕玻璃 增益系数 增益一致性 
中国激光
2011, 38(3): 0302009
Author Affiliations
Abstract
Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800
Experimental investigation was performed with a 1064-nm, 10-ns Nd:YAG laser to determine the effects of the surface hydrogen acid etching on laser damage, compared with damage of conventionally polished surface. The investigation was helpful for us to understand the negative effects of Nd-doped phosphate glass surface and subsurface damage (SSD) on laser induced damage threshold (LIDT). A set of samples was polished, and then chemically etched in a cool buffered 10%HF + 20%H2SO4 solution at different times. Another set of samples was ground and etched in the hot-buffered solution, and then polished. All the samples were irradiated with Nd: YAG laser and characterized by optical microscopy. Results of LIDT were obtained according to International standard ISO/DIS 11254-1.2. Chemical treatment can remove the contaminants in the polished re-deposition layer and the SSD for improving the laser damage resistance of Nd-doped phosphate glass surfaces. The method of using hot solution was more effective than that of using cool solution.
亚表面缺陷 激光损伤 磷酸盐激光玻璃 140.3330 Laser damage 140.3530 Lasers, neodymium 240.6700 Surfaces 
Chinese Optics Letters
2008, 6(9): 681
作者单位
摘要
中国科学院上海光学精密机械研究所, 上海 201800
建立了用于光学元件和材料的激光(1064 m与355 nm)损伤阈值测试平台.按照IsO-DIS 11254-1.2的测试规范,采用l-on-1打点与激光损伤几率的方法给出被测样品的激光损伤阈值.研制了激光光斑有效面积测试装置,提高了光学元件激光损伤阈值的测试精度.
激光技木 激光损伤阈值 有效面积 损伤几率 
中国激光
2004, 31(s1): 430
Author Affiliations
Abstract
中国科学院上海光学精密机械研究所, 上海 201800
The system for effective area measurement of laser spot on target plane was designed based on the definition of effective area. A 12-bit CCD camera is used for the effecive area measurement. A bmp image of the beam profile is stored. This image is processing by software to evaluate the ratio of total energy and peak fluence (effective area). Some test results were given using effective area measurement system. The system was employed in the laser induced damage threshold test and it is helpful to improving the precision of laser induced damage threshold test.
光斑有效面积 激光损伤阈值 准确测量 峰值能量密度 Spot effective area Laser induced damage threshold 
Collection Of theses on high power laser and plasma physics
2004, 2(1): 83
作者单位
摘要
中国科学院上海光学精密机械研究所, 上海 201800
从激光光斑有效面积的定义出发,采用CCD图像摄取技术,设计了一套激光光斑有效面积测量装置.在4种不同激光光斑能量分布和不同能量密度的情况下,用有效面积测量仪分别进行了实际测试验证.结果表明,该测量装置可以对任何能量非均匀分布的激光光斑的有效面积进行准确测试,有助于提高光学元件激光损伤阈值的测量精度.
光斑有效面积 激光损伤阈值 准确测量 峰值能量密度 Spot effective area Laser induced damage threshold 
强激光与粒子束
2004, 16(10): 83
Author Affiliations
Abstract
1 高功率激光物理国家实验室,中国科学院上海光学精密机械研究所,上海,201800
2 高功率激光物理国家实验室,上海激光等离子体研究所,上海,201800
3 中国工程物理研究院激光聚变研究中心,四川,绵阳,621900
4 上海激光等离子体研究所,上海,201800
Nd∶doped-glass-based sub-picosecond laser system with the maximum peak power of greater than 20 tara watts and the energy on target surface of 16 J is accomplished by using the chirped laser pulse amplification technology. While the laser pulse is focused by an off-axis parabolic mirror, the power density on target surface of approximately 2×10 18 W/cm 2 is acquired. In the performed neutron experiment, a C 8D 8 plate target is placed on the focal spot of the off-axis parabolic mirror. The maximum neutron yield for a single shot reaches 2.4×10 4. Still some other related problems are discussed
惯性约束聚变技术 亚皮秒超短脉冲激光 钕玻璃放大器 中子产额 ICF sub-picosecond ultra short laser pulse Nd∶doped glass based amplifier neutron yield 
Collection Of theses on high power laser and plasma physics
2003, 1(1): 17
作者单位
摘要
1 高功率激光物理国家实验室,中国科学院上海光学精密机械研究所,上海,201800
2 高功率激光物理国家实验室,上海激光等离子体研究所,上海,201800
3 中国工程物理研究院激光聚变研究中心,四川,绵阳,621900
4 上海激光等离子体研究所,上海,201800
利用啁啾脉冲放大技术,建成了一台基于钕玻璃放大器1053 nm波长的亚皮秒超短脉冲激光系统(SPS)。系统的输出峰值功率大于20 TW,靶面最高能量可达16 J,采用离轴抛物面反射镜聚焦,在靶面上获得2×10 18 W/cm 2的激光功率密度,以此激光脉冲轰击氘化聚苯乙烯平面靶,获得单次发射最高2.4×10 4个中子产额。对中子产生的机理进行了相关的讨论。
惯性约束聚变技术 亚皮秒超短脉冲激光 钕玻璃放大器 中子产额 
中国激光
2003, 30(10): 17
作者单位
摘要
1 上海交通大学物理系, 上海 200240
2 中国科学院上海光学精密机械研究所高功率激光物理国家实验室, 上海 201800
针对激光放大过程中的增益窄化效应,采用了窄带干涉滤光片与石英双折射滤光片两种器件对中心波长1053 nm,谱宽13 nm的超短脉冲进行光谱整形。石英晶片的参数由计算机仿真确定。光谱整形的实验结果与数值模拟的结果吻合较好。整形后的光谱形状变为平顶,谱宽增加了2 nm。
激光技术 超短脉冲 光谱整形 干涉滤光片 双折射滤光片 
中国激光
2003, 30(12): 1075
作者单位
摘要
中国科学院上海光机所,上海 201800
用Jones算法讨论了半波片和偏振片组合衰减装置的一般特性,得出了衰减量控制精度的表达式。最后给出了φ45 mm石英晶体半波片和偏振片组合衰减装置的实验结果。
衰减器 半波片 偏振光系统 
中国激光
1999, 26(1): 47
作者单位
摘要
中国科学院上海光学精密机械研究所, 上海 201800
从理论上分析了影响三倍频能量测量绝对精度和相对精度的若干因素。并且通过简单的模拟实验,验证了入射角对平板取样分光比的影响。提出了三倍频能量测量中消除杂散光影响的一些特殊的技术措施。
三倍频能量测量 精度 
光学学报
1997, 17(6): 750

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索