Author Affiliations
Abstract
1 Engineering Research Center of Precision Photonics Integration and System Application, Ministry of Education & Key Laboratory of Intelligent Optical Sensing and Manipulation, Ministry of Education & National Laboratory of Solid State Microstructures & College of Engineering and Applied Sciences & Institute of Optical Communication Engineering & Nanjing University-Tongding Joint Lab for Large-Scale Photonic Integrated Circuits, Nanjing University, Nanjing 210023, China
2 College of Electronics and Optical Engineering and College of Flexible Electronics, Nanjing University of Posts and Telecommunications, Nanjing 210023, China
3 The 41st Research Institute of China Electronics Technology Group Corp, Qingdao 266000, China
The stable long-distance transmission of radio-frequency (RF) signals holds significant importance from various aspects, including the comparison of optical frequency standards, remote monitoring and control, scientific research and experiments, and RF spectrum management. We demonstrate a scheme where an ultrastable frequency signal was transmitted over a 50 km coiled fiber. The optical RF signal is generated using a two-section distributed feedback (DFB) laser for direct modulation based on the reconstruction equivalent chirp (REC) technique. The 3-dB modulation bandwidth of the two-section DFB laser is 18 GHz and the residual phase noise of -122.87 dBc/Hz is achieved at 10-Hz offset frequency. We report a short-term stability of 1.62×10-14 at an average time of 1 s and a long-term stability of 6.55×10-18 at the measurement time of 62,000 s when applying current to the front section of the DFB laser. By applying power to both sections, the stability of the system improves to 4.42×10-18 within a testing period of 56,737 s. Despite applying temperature variations to the transmission link, long-term stability of 8.63×10-18 at 23.9 h can still be achieved.
frequency dissemination two-section DFB laser phase stability 
Chinese Optics Letters
2024, 22(1): 013903
作者单位
摘要
1 西安应用光学研究所,陕西 西安 710065
2 中国人民解放军 93427部队
反射式高分辨力光学系统是未来机载望远系统的发展方向。当光学系统工作在航空平台,由于受温度变化、振动冲击等因素的影响,光学系统将存在失调误差,需要对其进行空中校正。建立了反射镜失调量与泽尼克(Zernike)系数之间的非线性函数数学模型,采用Bhattacharyya系数方法去除相关性强的失调量,减少空中装调的复杂程度,增加可靠性。经过校正某同轴三反消像散系统,计算结果表明,系统的波像差均方根值(RMS)减小到0.025 λ,与设计值相差小于0.014 λ,满足空中装调需求。
机载光学系统 失调 空中校正 Zernike系数 airborne optical system misalignment aerial correction Zernike coefficient 
应用光学
2023, 44(4): 763
Author Affiliations
Abstract
1 Key Laboratory of Intelligent Optical Sensing and Manipulation of the Ministry of Education & Nanjing University-Tongding Joint Lab for Large-scale Photonic Integrated Circuits & National Laboratory of Solid-State Microstructures & College of Engineering and Applied Science & Institute of Optical Communication Engineering, Nanjing University, Nanjing 210093, China
2 Department of Photonics and Institute of Electro-Optical Engineering, Taiwan Sun Yat-sen University, Kaohsiung 80424, China
In this Letter, we proposed and experimentally demonstrated a directly modulated tunable laser based on the multi-wavelength distributed feedback (DFB) laser array. The lasers are placed in series to avoid the usage of an optical combiner and additional power loss. A three-section design is utilized to reduce the interference from other lasers and improve the electro-optic response bandwidth. Besides, the reconstruction-equivalent-chirp technique is used to simplify the grating fabrication and precisely control the grating phase. We realized 12 channels with 100 GHz spacing with high side mode suppression ratios of above 50 dB. The output power of all the channels is above 14 mW. The 3 dB electro-optic bandwidth is above 20 GHz at a bias current of 100 mA for all four lasers. A 25 Gb/s data transmission over a standard single-mode fiber of up to 10 km is demonstrated for all 12 channels, and 50 Gb/s data per wavelength is obtained through the four-level pulse amplitude modulation. The proposed directly modulated tunable in-series DFB laser array shows the potential for a compact and low-cost light source for wavelength division multiplexing (WDM) systems, such as next-generation front-haul networks and passive optical networks.
tunable laser directly modulated laser laser array wavelength division multiplexing 
Chinese Optics Letters
2023, 21(1): 011403
作者单位
摘要
南京航空航天大学材料科学与技术学院, 江苏 南京 211106
用ER4047焊丝对厚度为2.0 mm的2060/2099铝锂合金进行双激光束双侧同步焊接实验,定量分析了晶粒尺寸对铝锂合金T型焊接接头力学性能的影响。实验结果表明,等轴细晶区内晶粒近似为圆形,当焊接热输入为46.16 J/mm时,晶粒的尺寸最小。随着随焊接热输入的增大,等轴细晶区的宽度逐渐增大,柱状晶尺寸逐渐减小,铝锂合金T型接头的焊缝熔合线区域发生局部软化现象,导致该区域内的显微硬度最低。T型环向拉伸实验结果表明,下熔合线区域为接头薄弱区,该区域内晶粒尺寸对焊接接头力学性能的影响也最大。焊趾处为应力集中区域,也是拉伸断裂的起始点。拉伸断裂过程中,裂纹由焊趾处逐渐扩展至下熔合线,最终在下熔合线的蒙皮处断裂。研究结果表明,熔合区内的晶粒尺寸越小,焊接接头的力学性能越好。
激光技术 双激光束双侧同步焊接 晶粒尺寸 力学性能 铝锂合金 
中国激光
2021, 48(10): 1002120
作者单位
摘要
南京航空航天大学材料科学与技术学院, 江苏 南京 211106
为研究能量配比系数(激光功率与电弧功率的比值)对铝合金激光-MIG复合焊接气孔的影响,采用X射线无损检测与金相显微组织观察法对6 mm厚6061铝合金激光-MIG复合焊接接头在能量配比系数为4.0、3.5、3.1下的气孔进行了分析。结果发现:激光功率对焊缝横截面底部熔宽的影响显著,增大电弧功率能有效增大复合作用区域的深度;在较高的能量配比系数下,焊缝内部气孔的直径较大,但其数量较少,气孔率较低;在焊缝横截面上,气孔主要分布在焊缝上部,下部较少;但是当能量配比系数降低至3.1时,气孔的分布趋于均匀,下部气孔数量增加显著,且工艺气孔的数量也有所增加。结果表明,提高激光功率的能量占比有利于降低气孔率。
激光技术 复合焊接 气孔 能量配比系数 6061铝合金 
中国激光
2020, 47(11): 1102004
Pan Dai 1,2Yu Zhou 1,2Leilei Wang 1,2Shangjing Liu 1,2[ ... ]Xiangfei Chen 1,2,*
Author Affiliations
Abstract
1 Key Laboratory of Intelligent Optical Sensing and Manipulation of the Ministry of Education, Institute of Optical Communication Engineering, Nanjing University, Nanjing 210093, China
2 National Laboratory of Solid State Microstructures, College of Engineering and Applied Sciences, Nanjing University, Nanjing 210093, China
Until now, a high-efficiency demodulation method for fiber Bragg grating (FBG) sensors has been a challenge. In this Letter, by employing multi-peak FBGs, an FBG sensor with a partial wavelength scan is proposed and initially demonstrated. By demodulating a near-symmetrical multi-peak FBG and an asymmetrical multi-peak FBG in the strain experiment, sensor sensitivities of 1.02 pm/με and 1.01 pm/με are measured for the interrogation system, respectively. The average demodulation deviations for the two sensors are 1.81% and 0.4%, respectively. The proposed method is expected to realize high-efficiency and low-cost FBG interrogators.
fiber Bragg grating fiber sensor multi-peak fiber Bragg grating 
Chinese Optics Letters
2020, 18(7): 071201
作者单位
摘要
西安应用光学研究所, 陕西 西安 710065
高精密红外靶标是红外成像领域的重点研究内容之一。基于张正友标定原理, 通过材料温度和表面辐射特性设计适合于红外标定的简便式精密靶标; 基于张正友标定方法的基本原理, 提出靶板设计的基本要素; 根据表面辐射机理、靶面特征点的几何位置关系及热力学原理, 设计高低辐射区域具有锐利分界线的靶板, 并借助成像原理分析靶板板面误差精度, 获得符合基本要素的简便式高精密靶标。对设计的靶标进行试验, 结果表明: 该靶板在较低温差载荷(相对于室温22 ℃)的作用下, 靶面高辐射区和低辐射区边界锐利, 能够为标定提供精确的特征点, 标定反投影均方根误差小于0.16 pixel, 适合于红外成像系统的高精密标校。
靶标系统 红外成像系统 相机标定 target system infrared imaging system camera calibration 
光学 精密工程
2019, 27(8): 1828
作者单位
摘要
1 四川大学华西药学院, 四川 成都 610041
2 四川中医药研究院, 四川 成都 610041
3 布鲁克光谱仪器公司, 北京 100081
提出了用近红外光谱技术快速测定川藏道地药材菥蓂子中指标成分黑芥子苷含量的方法。对黑芥子苷含量在1.962%~3.917%范围的不同来源的菥蓂子,根据其在12500-3600cm^-1的近红外吸收光谱,采用偏最小二乘法(PLS)建立了校正模型,比较了光谱不同预处理方法对校正结果的影响。当采用最大最小归一化法时能最有效地提取光谱的信息,此时校正集相关系数(r)为0.9898,校正集标准偏差(SEC)为0.0233,预测集标准偏差(SPE)为0.1112。该方法快速简便,适合于重要指标成分的快速分析。
近红外漫反射光谱 菥蓂 菥蓂子 黑芥子苷 偏最小二乘法 Near infrared diffuse reflectance spectroscopy Thlaspi arvense Linn Semen Thlaspi Sinigrin PLS 
光谱学与光谱分析
2009, 29(10): 2673

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!