光学学报, 2003, 23 (10): 1168, 网络出版: 2006-06-27
光纤拉曼测温系统的温度标定及设计考虑
Physical Essentials and Design Considerations of Temperature Calibrationfor Distributed Optic Fiber Raman Temperature Sensing System
摘要
分布式光纤拉曼测温系统的重要参量之一是其温度测量精度,系统的温度标定对温度测量精度有着极其重要的影响。从该类系统的工作原理出发揭示了进行温度标定的物理原因及其对系统测温精度的影响程度。同时提出了在标定装置的实际设计上所要注意的几个方面。
Abstract
The temperature calibration has an important impact on the temperature accuracy, which is one of the two key performance parameters of distributed fiber optic temperature sensing systems. The physical essentials of temperature calibration is revealed and its effect on system temperature accuracy is analyzed. Some considerations and suggestions for practical temperature calibration design have been proposed.
刘建胜, 李铮. 光纤拉曼测温系统的温度标定及设计考虑[J]. 光学学报, 2003, 23(10): 1168. 刘建胜, 李铮. Physical Essentials and Design Considerations of Temperature Calibrationfor Distributed Optic Fiber Raman Temperature Sensing System[J]. Acta Optica Sinica, 2003, 23(10): 1168.