中国激光, 2024, 51 (5): 0511005, 网络出版: 2024-03-20  

基于傅里叶变换红外光谱技术观测海边大气水汽及其稳定同位素

Observation of Atmospheric Water Vapor and Its Stable Isotopes at the Seaside Based on Fourier Transform Infrared Spectroscopy
吴鹏 1,2单昌功 2,5,6,7,*王薇 2谢宇 4祝钱钱 1,2梁彬 1,2曾祥昱 1,2彭璇 1,2刘诚 1,3
作者单位
1 中国科学技术大学,安徽 合肥 230031
2 中国科学院合肥物质科学研究院安徽光学精密机械研究所,安徽 合肥 230026
3 中国科学技术大学精密机械与精密仪器系,安徽 合肥 230026
4 合肥学院自动化系,安徽 合肥 230601
5 中层大气和全球环境探测重点实验室,北京 100084
6 粤港澳环境质量协同创新联合实验室,广东 广州 510000
7 国家环境保护大气复合污染来源与控制重点实验室,北京 100084
摘要
傅里叶变换红外光谱(FTIR)技术已被广泛用于监测环境大气中的温室气体和痕量污染气体。本课题组基于便携式傅里叶变换红外光谱仪(EM27/SUN)收集的近红外太阳吸收光谱,利用非线性最小二乘拟合光谱反演算法,反演了深圳市沿海大气水汽及其稳定同位素HDO的柱浓度,并计算了水汽同位素比值δD以及水汽蒸散同位素δDET。在2023年2月27日到3月11日观测期间,干空气柱平均摩尔混合比XH2O的平均值为3226.11 mg/kg,标准偏差为27.42 mg/kg,ln (XH2O)与大气地表温度高度相关,相关系数为0.94。观测期间,水汽同位素比δD在-122.52‰和-16.54‰之间变化。利用Rayleigh蒸馏模型理解δD与水汽柱浓度之间的关系,结果发现ln(δD×1000+1)与ln(XH2O)之间有着显著的相关性(R=0.74),表明该地区大气水汽稳定同位素变化与水汽系数变化有着较大的相关性。最后,利用Keeling比值分析方法进行分析,结果显示,大气水汽蒸散同位素特征δDET在(-289.92±8.89)‰和(21.79±7.19)‰之间变化。便携式FTIR光谱仪及其测量方法能够被用于准确观测大气水汽及其稳定同位素的时间变化,为海边大气水循环研究提供了基础数据。
Abstract
Objective

Water vapor, the most prevalent greenhouse gas in Earth’s atmosphere, plays a pivotal role in atmospheric chemistry and climate dynamics. Its sources, sinks, and transportation mechanisms are integral to the hydrological cycle. Analyzing the isotopic composition of water vapor sheds light on diverse hydrological processes. Furthermore, concurrent observations of atmospheric water vapor and its isotopes offer insights into the origins of atmospheric humidity across various regions. Ground-based Fourier Transform Infrared Spectroscopy (FTIR) technology is a powerful tool for remotely sensing atmospheric gases through the collection of solar spectra, characterized by high accuracy and precision. A portable FTIR spectrometer is employed to conduct continuous observations at the Shenzhen Observatory over a period of approximately two weeks. It successfully collects the solar near-infrared (NIR) spectra of the coastal atmosphere, leading to the derivation of measurement results for water vapor and its stable isotopes in the ambient atmosphere through sophisticated inversion techniques.

Methods

The experimental setup for this study primarily included a portable FTIR spectrometer, an automated sun tracker, a comprehensive meteorological station, and a dedicated computer system. This spectrometer utilized natural sunlight as its primary incident light source, while the sun tracker continuously and accurately followed the sun’s position in real time. The solar rays were precisely channeled into the interferometer, where the resulting interference pattern was captured by a sensitive detector. This pattern was then transformed into a detailed NIR spectrum through a Fourier transform process. The spectrometer was designed to capture a NIR spectral range spanning 5000‒11000 cm-1, offering a spectral resolution of 0.5 cm-1. The core of the analysis lay in the utilization of a sophisticated non-linear least squares iterative algorithm, which enabled precise inversion of the vertical column concentration of the target gas. This involved a two-step process: initial forward modelling followed by meticulous spectral iterative fitting calculations. Upon determining the vertical column concentration of the sample gas, the dry air mole fraction (DMF) was then derived by correlating it with the total column concentration of dry air.

Results and Discussions

In our study, several specific spectral window bands are meticulously selected for the inversion of characteristic absorption features of atmospheric H2O and its isotope, HDO, in NIR spectroscopy. The average root mean square error of the residual fits for H2O and HDO spectra stands at 0.026% and 0.032%, respectively (Fig.2, Fig.3). This small residual indicates a high-quality fit to the solar spectra. During the observation period, the mean molar mixing ratio of water vapor (XH2O) in the dry air column demonstrates an increasing trend, with a standard deviation of 27.42 mg/kg. Notably, the peak concentration of XH2O is recorded at 5298.21 mg/kg on March 11, exhibiting a daily variation range of 1111.69 mg/kg, while the minimum value of 1377.45 mg/kg occurs on March 6, with a much narrower daily variation range of 323.09 mg/kg (Fig.6). To explore the relationship between surface XH2O and temperature during this period, a correlation analysis is performed, revealing a strong correlation between the natural logarithm of XH2O ln(XH2O) and surface temperature, evidenced by a high correlation coefficient of 0.94 (Fig.7). Regarding the isotopic ratio of water vapor (δD), our observations indicate a variation range from -122.52 ‰ to 16.54‰, averaging at -72.83 ‰. The lowest δD value, averaging at -103.43‰, is measured on March 6, while the highest average value of -53.36‰ is observed on March 3 (Fig.8). These δD values are primarily influenced by factors such as humidity, characteristics of water vapor evaporation, and the isotopic composition of the atmosphere in the measurement area. Employing the Keeling ratio method, we observe the water vapor evaporation characteristics of the coastal city. The evaporative δDET during the measurement period varies between (-289.92±8.89)‰ and (21.79±7.19)‰, averaging at (-111.85±14.51)‰ (Fig.11). The significant variability in δDET values in the Shenzhen area can be attributed to its coastal location, where evaporation predominantly originates from the sea. This evaporation process is influenced by various factors, including sunlight, temperature, wind force, and humidity.

Conclusions

This study utilizes near-infrared solar absorption spectra captured by a portable Fourier Transform Infrared (FTIR) spectrometer. We employ the advanced PROFFAST inversion algorithm to accurately derive the column concentrations of atmospheric H2O and its isotope, HDO. A key aspect of our experiment involves vigilant monitoring of the Instrument Line Shape (ILS) and Xair, revealing that the spectrometer maintains excellent long-term measurement stability. We simultaneously correct portable FTIR instrument readings with high-resolution FTIR instrument readings. Our research, leveraging the portable FTIR spectrometer, focuses on the coastal atmosphere of Shenzhen. We successfully measure water vapor and its isotopes, yielding valuable data on the column concentration of water vapor, the water vapor isotope ratio, and the characteristics of water vapor evapotranspiration during the measurement period. These results demonstrate the spectrometer’s capability to precisely monitor variations in water vapor and its stable isotopes in a coastal atmospheric setting. The data provided by these measurements offer a robust scientific foundation for understanding and tracking the diffusion and transport dynamics of water vapor in the ambient atmosphere. In future, our research endeavors will concentrate on the accurate retrieval of the water vapor isotope H218O from solar absorption spectra. By integrating data on H2O, HDO, and H218O, we aim to achieve a more comprehensive understanding of the water cycle, enhancing our insights into its complexities and interactions within the Earth’s atmosphere.

吴鹏, 单昌功, 王薇, 谢宇, 祝钱钱, 梁彬, 曾祥昱, 彭璇, 刘诚. 基于傅里叶变换红外光谱技术观测海边大气水汽及其稳定同位素[J]. 中国激光, 2024, 51(5): 0511005. Peng Wu, Changgong Shan, Wei Wang, Yu Xie, Qianqian Zhu, Bin Liang, Xiangyu Zeng, Xuan Peng, Cheng Liu. Observation of Atmospheric Water Vapor and Its Stable Isotopes at the Seaside Based on Fourier Transform Infrared Spectroscopy[J]. Chinese Journal of Lasers, 2024, 51(5): 0511005.

引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!