红外与激光工程, 2023, 52 (10): 20230077, 网络出版: 2023-11-21  

全彩单像素内窥成像系统

Full-color single-pixel endoscopic imaging system
作者单位
1 中国科学技术大学生物医学工程学院(苏州),江苏 苏州 215163
2 中国科学院苏州生物医学工程技术研究所,江苏 苏州 215163
摘要
单像素成像技术以其较强的弱光探测能力和较宽的工作波段在生物医学成像领域有着广阔的应用前景。通过将单像素成像技术与内窥成像技术相结合,提出两种腹腔镜全彩单像素内窥成像技术方案:一种是RGB三色光源方案将颜色和空间信息分别按时序分配给照明和检测双方,另一种是白光光源方案通过三个探测器同时采集颜色和空间的信息。搭建了两种腹腔镜全彩单像素内窥成像系统,设计了模块化的单像素相机,以多色彩条和肠道模型为成像目标,通过实验从峰值信噪比、结构相似度和成像速度等方面,系统量化分析了两种全彩单像素内窥成像系统的技术指标。实验结果表明,两种方案峰值信噪比和结构相似度接近,而白光光源方案成像速度更快,可以适配各种腹腔镜进行内窥成像,为推动单像素成像在内窥成像领域的应用提供了理论指导。
Abstract
ObjectiveSingle-pixel imaging (SPI) technology has excellent application prospects in biomedical imaging because of its weak light detection ability and wide working band. In recent years, some research works on full-color SPI imaging methods have been reported one after another. The current technical route of full-color SPI is roughly divided into two directions: one is to use RGB trichromatic light sources for illumination, to capture the light intensity after modulation of different color light through a single-pixel detector respectively, and finally to synthesize full-color images through reconstructed RGB three-channel images. The other is to use a white light source for illumination and capture the color and spatial information of the target scene through a beam-splitting prism and multiple single-pixel detectors. With the rapid development of single-pixel imaging technology, some researchers have applied full-color single-pixel imaging technology to biomedical imaging systems. However, most of them only apply full-color single-pixel imaging to wide-field imaging systems without taking full advantage of the low light detection ability and a broad spectrum of single-pixel imaging technology. Moreover, most of the optical imaging systems built in the laboratory are only validation prototypes, and further modularization and miniaturization of them have yet to be developed. Therefore, it is necessary to combine full-color single-pixel imaging technology and endoscopic imaging technology to design and build a modular and miniaturized full-color single-pixel endoscopic imaging system. To this end, two full-color SPI endoscopic imaging systems were designed and built by combining the two main technical routes of full-color SPI with endoscopic imaging technology. The advantages and disadvantages of the two full-color SPI endoscopic imaging schemes were systematically analyzed. Moreover, the modular and miniaturized design and modification according to the proposed imaging scheme make it possible to match various laparoscopes for endoscopic imaging.MethodsTwo modular full-color single-pixel imaging systems were designed and built based on Hadamard single-pixel imaging technology. The system's optical paths and modular schematics are shown in Fig.2 and Fig.4. The experimental setup used the group's self-developed four-band LED light source box as the light source, a digital micromirror device (DMD) as the spatial light modulator, and silicon-based photodetectors as the single-pixel detectors. The two full-color single-pixel imaging systems were used to perform endoscopic imaging experiments on the color bars. The reconstructed images of the color bars of the two imaging schemes were compared and analyzed using PSNR and SSIM as evaluation criteria (Tab.1). The imaging times of the color bar endoscopic imaging experiments of the two imaging schemes were also analyzed for comparison (Tab.2). Further endoscopic imaging experiments were performed on human intestinal models using a modular full-color single-pixel system.Results and DiscussionsThe PSNR of the RGB trichromatic light scheme was 18.5717 dB, SSIM was 0.6431, and total imaging time was 6.5506 s. The PSNR of the white light scheme was 18.4988 dB, SSIM was 0.6860, and total imaging time was 3.8726 s. The difference between the PSNR of the white light scheme and the RGB trichromatic scheme is only 0.0729 dB. However, the SSIM of the white light scheme is 0.0429 higher than that of the RGB trichromatic scheme. The measurement time of the white light scheme is shorter than that of the RGB trichromatic scheme by one-third, and the reconstruction time is shorter by 0.012 s. Therefore, the total imaging time of the white light scheme is 2.678 s faster than that of the RGB trichromatic scheme. From the experimental results, the white light scheme is more suitable for the endoscopic imaging system. The human intestinal model was imaged using the white light scheme, and the results are shown in Fig.7. Complex targets can also be imaged, which can meet the needs of endoscopic imaging.ConclusionsTwo full-color single-pixel endoscopic imaging systems were designed and built. A quantitative comparison of the two proposed imaging schemes was made to analyze their advantages and disadvantages. By calculating the imaging quality and time, the white imaging scheme is more suitable for the full-color endoscopic imaging system than the RGB tri-color scheme. Meanwhile, the two imaging systems are miniaturized and modularized to be adapted to various types of laparoscopes for endoscopic imaging.

杨旭, 冉悦, 周伟, 徐宝腾, 刘家林, 杨西斌. 全彩单像素内窥成像系统[J]. 红外与激光工程, 2023, 52(10): 20230077. Xu Yang, Yue Ran, Wei Zhou, Baoteng Xu, Jialin Liu, Xibin Yang. Full-color single-pixel endoscopic imaging system[J]. Infrared and Laser Engineering, 2023, 52(10): 20230077.

引用该论文: TXT   |   EndNote

相关论文